Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Rev. bras. ciênc. vet ; 29(1): 13-18, jan./mar. 2022. il.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1393188

RESUMO

As fístulas oronosais adquiridas são defeitos que permitem a comunicação anormal entre as cavidades oral e nasal. Inúmeras causas podem ser atribuídas à etiologia de tal defeito. O presente trabalho visa relatar o caso de um cão com fístula oronasal adquirida que foi submetido à reconstrução cirúrgica do palato com o uso de malha de polipropileno e prótese acrílica. Após estabilização do quadro clínico e remoção manual das larvas, o paciente foi encaminhado para o desbridamento cirúrgico das lesões orais e correção do defeito no palato. A palatoplastia foi realizada com o uso da malha e resina de polimetilmetacrilato autopolimerizável. A malha foi suturada sobre o defeito palatino com pontos simples separados e fio náilon 3-0 nas extremidades da ferida. Em seguida, a resina foi preparada e, ao atingir consistência adequada, foi aplicada e modelada sobre o a malha de polipropileno com o auxílio de um descolador de Molt, sendo também suturada nas bordas da fístula com pontos simples separados e fio náilon 3-0. No mesmo tempo cirúrgico foi inserida uma sonda esofágica para alimentação enteral. Devido complicações cirúrgicas no pós operatório, o paciente foi submetido a mais duas intervenções cirúrgicas para desfecho satisfatório do tratamento. Conclui-se que associação entre a tela de polipropileno e a prótese acrílica foi uma alternativa exequível para a palatoplastia em cão.


Acquired oronosal fistulae are abnormal communication between the oral and nasal cavities. A oronasal fistula can be the result of different causes, like oral myiasis. The objetctive of these paper is to report the case of a dog with acquired oronasal fistula that underwent surgical reconstruction of the palate using polypropylene mesh and acrylic prosthesis. After stabilization of the patient ́s clinical condition and mecanic removal of the larvae, the dog was referred for surgical debridement of the oral lesions and correction of the defect in the palate. Palatoplasty was performed using a mesh and polymethylmethacrylate resin. The mesh was sutured over the palatal defect with separate simple suture and 3-0 naylon thread at the ends of the wound. Then, the resin was prepared and, upon reaching adequate consistency, it was applied and shaped over the polypropylene mesh with Molt peeler. It was also sutured on the edges of the fistula with separate simple suture and 3-0 nylon suture. At the same surgical time, an esophageal tube was inserted for enteral feeding. Due to complications, the dog underwent two more surgical interventions for a satisfactory treatment outcome. It is concluded that the association between the polypropylene mesh and the acrylic prosthesis was a practical alternative for palatoplasty in dogs after oral myiasis.


Assuntos
Animais , Cães , Obturadores Palatinos/veterinária , Palato/cirurgia , Polipropilenos , Próteses e Implantes/veterinária , Fístula Bucal/veterinária , Procedimentos de Cirurgia Plástica/veterinária , Cães/cirurgia , Miíase/veterinária
2.
Arq. bras. med. vet. zootec. (Online) ; 72(1): 107-114, Jan.-Feb. 2020. tab, ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-1088916

RESUMO

O objetivo deste trabalho foi mensurar as dimensões da patela de cadáveres caninos e avaliar sua relação com a massa corporal. Para a realização das medidas patelares, foram utilizados 70 cadáveres de cães adultos, com massa corpórea de 1 a 50kg, sem evidência clínica de afecção na articulação femorotibiopatelar. Com auxílio de um paquímetro, foram mensurados os comprimentos externo e interno, a largura externa no terço médio, a largura e a espessura internas nos terços proximal, médio e distal das patelas. Também foram mensuradas a largura nos terços proximal, médio e distal, a profundidade nos terços proximal, médio e distal do sulco troclear; essas medidas foram exclusivamente internas. Observou-se, de forma geral, forte correlação entre as medidas patelares e a massa corporal de cadáveres de cães. Nas condições deste estudo, pode-se concluir que o tamanho da patela varia segundo a massa corporal do cão e que essas medidas devem ser consideradas ao se planejar uma substituição protética.(AU)


The aim of this study was to measure the canine cadaver patellar dimensions and evaluate its relationship with body mass. 70 cadavers of adult dogs were used, with a body mass between 1 and 50kg, without clinical evidence of affection in the stifle joint. The external and internal lengths, external width in the middle third, width and thickness of the proximal, middle and distal thirds were measured using a pachymeter. The width was also measured in the proximal third, middle third and distal third, depth in the proximal third, middle third and distal third of the trochlear groove; these measurements were exclusively internal. A strong correlation was observed between the patellar dimension and body mass of canine cadavers. Under this study conditions, it is possible to conclude that the patellar size varies according to the canine body mass and these measures should be considered when planning a prosthetic replacement.(AU)


Assuntos
Animais , Cães , Patela/anatomia & histologia , Próteses e Implantes/veterinária , Peso Corporal , Luxação Patelar/veterinária , Cadáver
3.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1038647

RESUMO

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Assuntos
Animais , Cães , Próteses e Implantes/veterinária , Procedimentos Ortopédicos/veterinária , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Tíbia
4.
Pesqui. vet. bras ; 37(12): 1474-1478, dez. 2017. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-895384

RESUMO

Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84®5,55o) e T1 (111,22o®3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6®4,70o e T1=110,06®10,61o, p<0,05) quanto no grupo HIB (T0=126,43®5,87o e T1=116,87®8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3®74,46N/mm) em relação ao grupo HIB (586,7®44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.(AU)


Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84®5.55o) and T1 (111.22o®3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6®4.70o e T1=110.06®10.61o, p<0.05) and IN group (T0=126.43®5.87o e T1=116.87® 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3®74.46N/mm) compared to IN group (586.7®44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.(AU)


Assuntos
Animais , Cães , Osteotomia/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Fixação Intramedular de Fraturas/veterinária , Displasia Pélvica Canina/terapia , Fraturas do Quadril/veterinária , Procedimentos Ortopédicos/veterinária
5.
Arq. bras. med. vet. zootec ; 69(2): 347-354, mar.-abr. 2017. ilus, tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-833830

RESUMO

Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna, sendo a osteossíntese minimamente invasiva com placa (Mipo) uma das recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasivas em fraturas da tíbia de cães, sem a utilização de intensificadores de imagem intraoperatória. Foram utilizados 10 cães que apresentavam fraturas da tíbia, de idades e raças variadas. Os animais foram avaliados quanto à deambulação, à intensidade do edema, e exames radiográficos foram realizados nos períodos zero, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório, 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema discreto a ausente no membro operado. Após 30 dias de pós-operatório, todos os cães já apoiavam o membro ao caminhar e não apresentavam formação de edema. Todos os pacientes apresentaram sinais radiográficos de início de consolidação óssea após 15 dias de pós-operatório e pôde-se observar que a união clínica ocorreu em média aos 42,5 dias. O tratamento de fraturas de tíbia por meio da Mipo é alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizado sem uso de intensificadores de imagem.(AU)


Advances in the comprehension of bone healing and complications of treatment of fractures have occurred. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the ways to avoid tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs, with no intraoperative imaging. Ten dogs presenting tibial fracture were used. Deambulation, swelling and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. After 15 days of surgery 80% dogs were able to walk with slight swelling or without swelling. After 30 days all dogs have supported the member to walk and had no swelling. All dogs presented initial radiographic signs of bone healing after 15 postoperative days and it can be seen that the average clinical union occurred at 42.5 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers.(AU)


Assuntos
Animais , Cães , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/veterinária , Próteses e Implantes/veterinária , Cicatrização
6.
Arq. bras. med. vet. zootec ; 68(6): 1440-1448, nov.-dez. 2016. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-827941

RESUMO

A artroplastia total da articulação coxofemoral é a técnica cirúrgica mais efetiva para o tratamento da displasia coxofemoral canina grave. Na atualidade, o exame radiográfico é o método mais utilizado para se avaliar esse procedimento em cães, porém possui algumas limitações. Já o exame tomográfico por meio de tomografia computadorizada possibilita a aquisição de imagens sem sobreposições e, dessa forma, a determinação do posicionamento dos componentes protéticos com maior precisão. A presente pesquisa teve como objetivo avaliar, por meio de exames radiográficos e tomográficos, a utilização de uma prótese total modular híbrida da articulação coxofemoral desenvolvida e confeccionada no Brasil, aplicada experimentalmente em cães sadios. Foram utilizados seis cães esqueleticamente maduros, previamente submetidos ao procedimento cirúrgico da articulação coxofemoral esquerda. Os cães foram submetidos ao exame tomográfico aos 360 dias e três anos após a cirurgia. Todos os animais apresentaram bom posicionamento dos componentes protéticos e redução articular adequada. Ao exame tomográfico, entretanto, foram detectadas áreas de preenchimento irregular em alguns animais. Adicionalmente, o exame tomográfico permitiu a detecção e monitoração de áreas de reabsorção óssea ao redor do componente acetabular. Assim, o exame tomográfico mostrou-se útil na avaliação das articulações protéticas, com a vantagem de apresentar ótima definição das imagens e permitir quantificar alterações periprotéticas e mensurar relações articulares, fundamentais para o acompanhamento pós-cirúrgico tardio.(AU)


The total hip arthroplasty is the most effective surgical technique for the treatment of severe canine hip dysplasia. Currently, the radiographic examination is the most common method used to assess this procedure in dogs, but has some limitations. CT scan by computed tomography instead enables the acquisition of images without overlap, thereby determining the positioning of prosthetic components with greater accuracy. This research aimed to evaluate by radiography and CT scan examinations the use of a hybrid modular total hip prosthesis developed and made in Brazil, applied experimentally in healthy dogs. Six skeletally mature dogs, which previously underwent surgery on the left hip joint were used. The dogs underwent CT scan at 360 days and three years after surgery. All animals showed good positioning of prosthetic components, and proper joint reduction. In the CT scan, however, it was possible to detect irregular fill areas in some animals. In addition, CT scan allowed the detection and monitoring of areas of bone resorption around the acetabular component. Therefore, the CT scan was useful in the evaluation of prosthetic joints, with the advantage of optimum sharpness of the images and allowing for the possibility of quantifying peri-prosthetic changes and measure joint, fundamental relations for late postoperative follow-up.(AU)


Assuntos
Animais , Cães , Artroplastia/veterinária , Displasia Pélvica Canina/cirurgia , Próteses e Implantes/veterinária , Diagnóstico por Imagem/veterinária , Tomografia Computadorizada por Raios X/veterinária
7.
Acta cir. bras ; 29(12): 1-7, 12/2014. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1456221

RESUMO

PURPOSE: To evaluate the performance of composites consisting of fragmented cortical bone heteroimplant in association with methylmethacrylate preserved in 98% glycerin, in segmental bone defect of rabbit tibia medial metaphysis. METHODS: In this study were used twelve adult New Zealand rabbits, divided into three groups of four animals each: G30 (30 days), G60 (60 days) and G90 (90 days). The bone defects previously created in the tibia were filled with composites and both were evaluated by cone-beam computed tomography, immediately after surgery and after 30, 60, and 90 days. RESULTS: The composites fulfilled and remained in the sites of bone defects in all cases and were not registered signals of infection, migration or rejection. CONCLUSIONS: The implanted composites promoted the bone defects repair without signals of infection and/or rejection. The composites are one more option for bone defects repair.


Assuntos
Animais , Coelhos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Materiais Biocompatíveis , Metilmetacrilatos , Próteses e Implantes/veterinária
8.
Pesqui. vet. bras ; 33(10): 1201-1207, Oct. 2013. ilus, graf
Artigo em Português | LILACS | ID: lil-697159

RESUMO

A evolução tecnológica tem possibilitado o desenvolvimento e o aperfeiçoamento de novos materiais para implantes. Apesar dos fundamentais benefícios providos pelos dispositivos ortopédicos, complicações decorrentes de corrosão, degradação, infecção, além de outras podem ocorrer. O entendimento das características dos biomateriais é fundamental para a previsibilidade do seu comportamento in vivo, fornecendo subsídios para que o composto mais adequado seja escolhido na reconstrução do defeito ósseo. As placas de origem metálica são as mais utilizadas para o reparo de fraturas de ossos longos, sendo mecanicamente resistentes e biocompatíveis. No entanto, a necessidade de remoção e o enfraquecimento do osso são suas principais desvantagens. Neste trabalho, placas produzidas a partir de osso cortical equino foram empregadas experimentalmente em fêmur osteotomizado de coelhos (Grupo osso-GO), num estudo comparativo com placas de metal (Grupo metal-GM). A avaliação radiográfica foi realizada a cada 30 dias, durante 120 dias, momento em que foi então realizada análise histológica do material em estudo. Não houve diferença estatisticamente significante entre os dois grupos com relação à morfometria do calo ósseo e consolidação óssea em todos os momentos avaliados, sendo que ambas as placas permitiram a consolidação em todos os animais. Entretanto, observou-se que o calo ósseo foi menor no GO, em relação ao GM, em todos os momentos do estudo. Por outro lado, a maior parte dos animais do GO apresentou consolidação completa da fratura aos 90 dias, enquanto que no GM isto ocorreu aos 60 dias. Não foram evidenciadas células do tipo corpo estranho na histopatologia dos animais do GO, mas maior quantidade de tecido fibroso foi identificada, envolvendo este biomaterial. A placa confeccionada com osso equino representa uma alternativa de baixo custo e muito viável, uma vez que permitiu estabilização adequada para consolidação óssea de fratura de fêmur em ...


Actually, technological advances have contributed to the development and improvement of new materials for implants. Despite the fundamental benefits provided by orthopedic materials, complications resulting from corrosion, degradation, infection, and others may occur. The knowledge of characteristics of the biomaterials is important to predict their behavior in vivo, supporting that the most suitable compound is chosen to reconstruct the bone defect. Metallic plates are the most common material used for repair of long bone fractures, and they are mechanically stable and biocompatible. However, the need of removal and bone weakening are their disadvantages. In this paper, plates made from equine cortical bone were used experimentally in osteotomized rabbit femur (bone-GO Group), in a comparative study with metal plates (metal GM Group). Radiographic evaluation was performed every 30 days during 120 days, at which time was then performed femur histological analysis. During all evaluated moments of the study, there was no statistically significant difference between the two groups in callus morphometry, and complete consolidation was observed in all animals. However, it was observed that the callus was lower in GO compared to GM, all times during the study. Moreover, most of the GO animals showed complete consolidation fracture at 90 days only, whereas this occurred in GM at 60 days. There were no foreign-body cells in the histopathology exam of the GO animals, but larger amount of fibrous tissue was identified, involving this biomaterial. The plate made from horse bone represents a low cost alternative and it is very feasible, it allowed adequate stabilization of femur fracture in rabbits. In this study, the lower periosteal callus associated with a longer time for consolidation in GO suggest greater fracture stability when the bone plate was used.


Assuntos
Animais , Adulto , Coelhos/lesões , Fixação de Fratura/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Radiografia/veterinária
9.
Braz. j. vet. res. anim. sci ; 47(1): 38-46, 2010. ilus
Artigo em Português | LILACS | ID: lil-557550

RESUMO

Duzentos e vinte e uma vacas (78 paridas com bezerros entre 40 e 90 dias de idade e as demais secas vazias) Nelore (Bos taurus indicus) e mestiças Charolês (Bos taurus taurus) foram utilizadas para avaliar a reutilização de implantes auriculares de silicone impregnados com progestágenos para controle farmacológico do ciclo estral e ovulação sobre a taxa de prenhez. Os tratamentos experimentais consistiram de três protocolos para sincronização do cio e inseminação artificial em tempo fixo (IATF). No tratamento 1 (T1; n=73) as vacas receberam um implante auricular de Crestar® (3 mg de norgestomet); no tratamento 2 (T2; n= 75) as vacas receberam um implante auricular de Crestar® já utilizado previamente; e no tratamento 3 (T3; n=73) as vacas receberam dois implantes auriculares de Crestar® também utilizados previamente. Além dos implantes, as vacas receberam aplicação intramuscular (i.m) 2 mL de progesterona (25 mg/mL) + 2 mL de benzoato de estradiol i.m (1 mg/mL) no momento da colocação dos implantes. Os implantes foram removidos após 8 dias junto a uma aplicação de 2,0 mL de Preloban® i.m (150 g de D-cloprostenol). Após 24 h da remoção do implante, aplicou-se 1 mL de Estrogin® i.m (1 mg de benzoato de estradiol). A IATF foi realizada 54-56 h após a retirada dos implantes. Não houve diferença na taxa de prenhez das vacas, sendo 39,72%, 34,21% e 36,98% para os tratamentos T1, T2 e T3, respectivamente. A reutilização de implantes com progestágeno (Crestar®) não alterou a taxa de prenhez de vacas aptas à reprodução.


Two-hundred and twenty-one (78 suckling - 40 to 90 days and 143 not suckling ) Nelore (Bos taurus indicus) and crossbred Charolais (Bos taurus taurus) cows were used to evaluate the reutilization of progestagen implants to pharmacological control of the estrus cycle and ovulation on pregnancy rate. Cows were randomly assigned to one of three protocols for estrous synchronization and pre-fixed time artificial insemination (FTAI) was performed. In treatment 1 (T1; n=73) cows were implanted with Crestar® (3 mg de norgestomet); in treatment 2 (T2; n= 75) cows were implanted with already used Crestar®, and in treatment 3 (T3; n=73) cows received two Crestar® implants, also both previously used. All cows were injected with 2 mL of progesterone (25mg/mL) + 1 mL estradiol benzoate (1 mg/mL i.m.) at the time of implants insertion, intramuscular (i.m). Implants were removed after 8 days and 2 mL of Preloban® (150 g de D-cloprostenol) were administered i.m. Twenty-four hours after implants removal, cows were injected with 1 mL (i.m.) of Estrogin® (1mg of estradiol benzoate). The FTAI was performed 54-56 h after implants removal. There was no difference (P>0.05) on cow’s pregnancy rate among treatments. Pregnancy rates were 39.72, 34.21 and 36.98% for T1, T2 and T3, respectively. Progestagen implants reutilization (Crestar®) did not affected pregnancy rate in beef cows ready for reproduction.


Assuntos
Animais , Feminino , Adulto , Ciclo Estral , Próteses e Implantes/métodos , Próteses e Implantes/tendências , Próteses e Implantes/veterinária , Prenhez/metabolismo , Bovinos , Inseminação Artificial/métodos , Inseminação Artificial/tendências , Inseminação Artificial/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA